FAST scanning in the developing world emergency department
Abstract
Objectives. To assess the utility of an existing ultrasound machine for the purposes of focused assessment sonography in trauma (FAST) scanning in a developing world emergency department (ED).Design. Prospective study undertaken over a 12-month period.
Trauma patients attending the ED were FAST scanned by one of three trained emergency medicine doctors.
Setting. The ED at a government hospital in rural KwaZulu-Natal (KZN), the referral centre for 22 peripheral hospitals.
Subjects. All patients presenting to the ED who had sustained
abdominal or thoracic trauma.
Outcome measures. Scans were recorded as positive or negative
for free intra-abdominal or pericardial fluid. All results were confirmed by computed tomography, laparotomy or a second trained ED ultrasonographer, followed by a period of clinical observation.
Results. 72 FAST scans were included, 52 for blunt trauma and
20 for penetrating trauma. Of the 72 scans, 15 (20.8%) were
positive. FAST scanning had 100% specificity and overall sensitivity of 71.4%. When considering blunt trauma alone the sensitivity improved to 81.3%, while in penetrating trauma it was much poorer (62.5%).
Conclusions. We propose a valuable role for FAST scanning
in all peripheral hospitals for the assessment of patients sustaining blunt trauma. In rural areas with limited resources FAST scans may assist in the appropriate timely transfer of trauma patients for further imaging or definitive surgical intervention.
Copyright remains in the Author’s name. The work is licensed under a Creative Commons Attribution - Noncommercial Works License. Authors are required to complete and sign an Author Agreement form that outlines Author and Publisher rights and terms of publication. The Agreement form should be uploaded along with other submissions files and any submission will be considered incomplete without it [forthcoming].
Material submitted for publication in the SAMJ is accepted provided it has not been published or submitted for publication elsewhere. Please inform the editorial team if the main findings of your paper have been presented at a conference and published in abstract form, to avoid copyright infringement. The SAMJ does not hold itself responsible for statements made by the authors.
Previously published images
If an image/figure has been previously published, permission to reproduce or alter it must be obtained by the authors from the original publisher and the figure legend must give full credit to the original source. This credit should be accompanied by a letter indicating that permission to reproduce the image has been granted to the author/s. This letter should be uploaded as a supplementary file during submission.